- Out-of-Stock

Benefits
- Pellets, Firewood and Oat Pellets
Twin Bio Luxury is compatible with all types of pellets, firewood and oat pellet mixes (50%/50%).
- Economy
The innovative Platinum Bio VG burner automatically adjusts its parameters to the building's heat demand.
- Extremely durable
All of our devices go through a series of tests to verify flow rates, resistance and voltages.
- Safety
When the controller receives information about an irregularity, the device is disabled and a message is displayed on the boiler controller.
- Internet module
All boiler and central heating system functions can be monitored remotely using a PC or a smartphone (optional).
- A complete heat solution
Security policy
Delivery policy
Return policy (edit with Customer reassurance module)
8 kW | 10 kW | 12 kW | 16 kW | 24 kW | 32 kW | ||
---|---|---|---|---|---|---|---|
Flue draught | mbar | 0,15 - 0,25 | 0,15 - 0,25 | 0,15 - 0,25 | 0,15 - 0,25 | 0,15 - 0,30 | 0,15 - 0,30 |
Water capacity | dm3 | 44 | 44 | 44 | 58 | 65 | 102 |
Maximum working pressure | bar | 2 | 2 | 2 | 2 | 2 | 2 |
Test pressure | bar | 4 | 4 | 4 | 4 | 4 | 4 |
Flue gas temperature at rated output | °C | 139,5 | 139,5 | 139,5 | 112,9 | 140,9 | 129,2 |
Flue gas temperature at minimum output | °C | 87,3 | 87,3 | 87,3 | 72,7 | 78,3 | 79,2 |
Flue gas mass flow at rated output | kg/h | 35,424 | 35,424 | 35,424 | 28,224 | 43,128 | 77,04 |
Flue gas mass flow at minimum output | kg/h | 21,096 | 21,096 | 21,096 | 14,436 | 17,496 | 29,268 |
Flue connector diameter | mm | 127 | 127 | 127 | 159 | 159 | 159 |
Flow resistance at 10 K | mbar | 1,4 | 1,4 | 1,4 | 1,9 | 5,5 | 9,5 |
Flow resistance at 20 K | mbar | 0,4 | 0,4 | 0,4 | 0,9 | 1,6 | 2,5 |
Rated heat output | kW | 4,2-14,5 | 4,2-14,5 | 4,2-14,5 | 4,4-15 | 7-24 | 8,7-32 |
Efficiency at rated output | % | 90,4 | 90,4 | 90,4 | 92,2 | 91,3 | 90,6 |
Efficiency at minimum output | % | 87,1 | 87,1 | 87,1 | 90,3 | 91,7 | 90,4 |
Boiler class as per EN 303-5:2012 | 5 | 5 | 5 | 5 | 5 | 5 | |
Combustion time at rated output (fuel calorific value: 17 280 kJ/kg) |
h | 85 | 85 | 85 | 52 | 34 | 22 |
Temperature controller settings range | °C | 50-80 | 50-80 | 50-80 | 50-80 | 50-80 | 50-80 |
Minimum water return temperature | °C | 45 | 45 | 45 | 45 | 45 | 45 |
Fuel type | Class | Sawdust granulate (pellets) made to EN 303-5:2012 / PN- EN ISO 17225-2 Class C1 / A1) Test fuel used in the certification procedure - A1. Also compatible with A2 and B class pellet.. |
|||||
Storage hopper capacity | l | 290 | 290 | 290 | 290 | 290 | 290 |
Rated heat output | kW | 8,3 | 10 | 12,2 | 15 | 24 | 32 |
Hopper dimensions | mm | 737x602 | 737x602 | 737x602 | 737x602 | 737x602 | 737x602 |
Power supply | V / Hz / A | 230 / 50 / 2 | 230 / 50 / 2 | 230 / 50 / 2 | 230 / 50 / 2 | 230 / 50 / 2 | 230 / 50 / 2 |
Power input at rated output | W | 56 | 56 | 87 | 82 | 128 | 74 |
Power input at minimum output | W | 20 | 20 | 25 | 23 | 27 | 39 |
Power input in STANDBY mode | W | 2 | 2 | 2 | 2 | 2 | 2 |
Maximum power input | W | 485 | 485 | 485 | 492 | 492 | 509 |
Maximum noise level | dB | 52 | 52 | 52 | 52 | 52 | 52 |
Fuel diameter | mm | 6 | 6 | 6 | 6 | 6 | 6 |