Bomba de calor 16KW SB-KHBRD016V_RSQ

€9,329.55
Tax included

This set contains:

16KW Low Temperature Three-Phase Outdoor Unit (ERLQ016CAW1).

Daikin Altherma 16KW 230V Low Temperature Indoor Unit (EHBX16CB3V).

Quantity
Out-of-Stock

 

Security policy

 

Delivery policy

 

Return policy (edit with Customer reassurance module)

rightbanner

rightbanner1

OUTSIDE UNIT

The outdoor unit draws heat from the outside air, even at -25°C;

Scroll compressor controlled by inverter.

INDOOR UNIT

Reversible wall-mounted air-to-water heat pump ideal for energy-efficient homes.

Features:

- Wall mounted indoor unit;

- Energy efficient heating and cooling system based on air-water heat pump technology;

- Perfect for new builds as well as low-energy housing;

- The best seasonal efficiencies, providing the greatest savings in operating costs;

- Flexible configuration regarding heat emitters;

- Possibility of combination with domestic hot water;

To heat Sanitary Hot Water you will need:

- Motorized valve 3 ways 1" 230V;

- Daikin DHW probe.

TECHNICAL DATA OUTSIDE UNIT

ERLQ016CAW1

dimensions

Unit

Height

mm

1,345

Width

mm

900

Depth

mm

320

Weight

Unit

kg

114

Pipe connections

liquid

OD

mm

9.52

Gas

OD

mm

15.90

Sewage

OD

mm

26

level difference

IU - OR

Max.

m

30.0

heat insulation

Liquid and gas tubes

sound power level

Heating

name

dBA

66 (3)

Cooling

name

dBA

69 (4)

sound pressure level

Heating

name

dBA

52 (5)

Cooling

name

dBA

54 (5)

refrigerant

Type

R-410A

GWP

2,087.5

Charge

TCO2Eq

7.1

Charge

kg

3.4

electrical supply

Name

W1

Phase

3N~

Frequency

Hz

50

Voltage

V

400

Chain

recommended fuses

THE

20

Grades

(1) - Operating limits for heating (outdoor unit): limit increase through support resistor. See separate diagram for operating limits.

(2) - Domestic hot water operating limit (outdoor unit): limit increase through backup booster heater. See separate diagram for operating limits.

(3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

(4) - Condition: Ta 35°C - LWE 7°C (DT = 5°C)

(5) - Sound pressure level is measured using a microphone at a certain distance from the unit. It is a relative value that depends on distance and acoustic environment. See the sound range diagram for more information.

(6) - Contains fluorinated greenhouse gases

TECHNICAL DATA INDOOR UNIT

EHBX16CB3V

casing

Color

White

Material

coated metal sheet

dimensions

Unit

Height

mm

890

Width

mm

480

Depth

mm

344

Weight

Unit

kg

44.0

ERP

Category

Art3§3, See note 1

sound power level

name

dBA

44.0 (4)

sound pressure level

name

dBA

30.0 (5)

electrical supply

Name

See note 11

electric heater

electrical supply

Name

3V3

Phase

1~

Frequency

Hz

50

Voltage

V

230

Wiring connections

To connect to the user interface

The amount

two

Observation

0.75 mm² to 1.25 mm² (max. length 500m)

Grades

(1) - PED unit category: excluded from the scope of PED due to article 1, item 3.6 of 97/23/EC

(2) - The operating area is extended at lower flow rates if the unit is operating with heat pump only. (Not available at start-up, no BHU operation, no defrost).

(3) - Including piping + PHE + backup heater; excluding expansion vessel

(4) - Bs/Bh 7°C/6°C-LWC 35°C (DT=5°C)

(5) - The sound pressure level is measured in an anechoic room 1 m away from the unit. It is a relative value, depending on distance and acoustic environment. The mentioned sound pressure level is the maximum possible value within the operating range of the unit.

(6) - 15°C-25°C: BUH only, no heat pump operation = during preparation

(7) - Lower if backup heater is installed; If there is no backup heater, then heat pump operation starts at 10°C

(8) - See operating range for differences between *RHQ* and *RLQ* models

(9) - If condensation is foreseeable, the installation of an EKHBDP* condensate tray kit must be taken into account.

(10) - > Only 50°C BSH, without heat pump operation

(11) - The power supply to the above mentioned hydro box is only for the backup heater. The junction box and the hydro box pump are supplied via the outdoor unit. The optional domestic hot water tank has a separate electrical supply.

(12) - The hydrobox junction box and pump are supplied via the outdoor unit. The optional domestic hot water tank has a separate electrical supply.

(13) - Equipment in accordance with EN/IEC 61000-3-12: European/International technical standard that defines the limits for harmonic currents produced by equipment connected to a public low voltage system with input current > 16A and ≤ 75A per phase

(14) - Select diameter and type according to national and local regulations

Daikin
32BCSB-KHBRD016V_RSQ

Specific References